Architecture and Planning Miscellaneous-topic
- Match the instruments in Column I with the various types of surveying in Column II and select the appropriate option.
Column I Column II P. Cross staff 1. Indoor wall to wall measurement Q. Alidade 2. Traversing R. Sextant 3. Chain survey S. Distomat 4. Plane table survey 5. Contour survey
-
View Hint View Answer Discuss in Forum
NA
Correct Option: D
NA
- For a symmetrical trapezoidal open drain in a landscape with grass and loose rock, surface, the velocity of flow of water is ___ m/sec, (round off to two decimal places), given the following data.
Water edge width at the top = 750 mm
Water edge width at the bottom = 45000 mm
Water depth = 600 mm
Manning’s coefficient of roughness = 0.05
Slope along the drain = 1 in 250
-
View Hint View Answer Discuss in Forum
Velocity of water (in m/sec) = 1 × r2 / 3 × S1 / 2 n
Here, n = 0.05Hydraulic radius , r = Wet area Wet perimeter = 0.36 = 0.2134 1.6869 S = 1 = 0.004 m 250 Velocity = 1 × (0.2134)2 / 3 × (0.004)1 / 2 = 0.45 m / sec 0.05 Correct Option: B
Velocity of water (in m/sec) = 1 × r2 / 3 × S1 / 2 n
Here, n = 0.05Hydraulic radius , r = Wet area Wet perimeter = 0.36 = 0.2134 1.6869 S = 1 = 0.004 m 250 Velocity = 1 × (0.2134)2 / 3 × (0.004)1 / 2 = 0.45 m / sec 0.05
- Match the thermal properties in the column I and their respective units in Column II and select the appropriate option.
Column I Column II P. Thermal resistance 1. J kg– 1°C– 1 Q. Thermal Transmittance 2. Wm– 1 °C– 1 R. Specific heat 3. Wm– 2°C– 1 S. Thermal Conductivity 4. m2°CW– 1 5. J m– 3°C– 1
-
View Hint View Answer Discuss in Forum
NA
Correct Option: B
NA
- As per the Handbook on Barrier Free and Accessibility, CPWD – 2014, match the design guidelines in Column I with their appropriate standards in Column II and select the appropriate option.
Column I Column II P. Minimum clear width of ramp 1. 600 mm Q. Maximum height of wash basin (rim) above finished floor level 2. 1500 mm R. Minimum length of grab rail 3. 750 mm S. Minimum clear width for manoeuvring space (wheel chair) 4. 900 mm 5. 1800 mm
-
View Hint View Answer Discuss in Forum
Refer the Handbook on Barrier Free and Accessibility, CPWD – 2014.
Correct Option: C
Refer the Handbook on Barrier Free and Accessibility, CPWD – 2014.
- An industrial building contains 3000 kg of combustible materials, in dry state, distributed over three rooms of area 100 m2, 500 m2 and 300 m2 each, in a proportion of 30%, 50% and 20% of the contents, respectively. Calorific value of the material is 4400 kCal/kg. The Total fire load of the rooms is equal to _______ kCal/m2.
-
View Hint View Answer Discuss in Forum
Fire Load = (Weight × Calorific Value) Area Fire Load in Room 1 = (300 × 0.3 × 4400) = 39600 kCal / sq m 100 Fire Load in Room 2 = (300 × 0.5 × 4400) = 13200 kCal / sq m 500 Fire Load in Room 3 = (300 × 0.2 × 4400) = 8800 kCal / sq m 300
Total Fire load = 39600 + 13200 + 8800 = 61600 kCal/sq mCorrect Option: D
Fire Load = (Weight × Calorific Value) Area Fire Load in Room 1 = (300 × 0.3 × 4400) = 39600 kCal / sq m 100 Fire Load in Room 2 = (300 × 0.5 × 4400) = 13200 kCal / sq m 500 Fire Load in Room 3 = (300 × 0.2 × 4400) = 8800 kCal / sq m 300
Total Fire load = 39600 + 13200 + 8800 = 61600 kCal/sq m