Electronic measurements and instrumentation miscellaneous
- An LVDT is used to measure displacement. The output of the LVDT is connected to a voltmeter of range 0 to 5V through an amplifier having a gain of 250. For a displacement of 0·5 mm, the output of the LVDT is 2 mV. The sensitivity of the instrument would be:
-
View Hint View Answer Discuss in Forum
Sensitivity of LVDT = output voltage displacement = 2mV 0·5mm
= 1V/mm.
Correct Option: C
Sensitivity of LVDT = output voltage displacement = 2mV 0·5mm
= 1V/mm.
- The deflection of hot wire instruments depends on:
-
View Hint View Answer Discuss in Forum
The deflection of not wire instruments depends on r.m.s. value of alternating current.
Correct Option: C
The deflection of not wire instruments depends on r.m.s. value of alternating current.
- Two voltmeters one with a full scale reading of 100 V and another with a full scale reading of 200 V, are connected in series across a 100 V supply. The internal resistance of both meters is the same. What are the readings?
-
View Hint View Answer Discuss in Forum
The given problem can be better understand by the figure given below:
Since both the voltmeter have same internal resistance and the voltmeter are connected in series across a 100V supply. Hence the reading of both the voltmeters will be same i.e. 50V.Correct Option: D
The given problem can be better understand by the figure given below:
Since both the voltmeter have same internal resistance and the voltmeter are connected in series across a 100V supply. Hence the reading of both the voltmeters will be same i.e. 50V.
- Which bridge is used for measuring audio and H.F. oscillations?
-
View Hint View Answer Discuss in Forum
Wein bridge is used for measuring audio and High frequency (H.F.) oscillations.
Correct Option: A
Wein bridge is used for measuring audio and High frequency (H.F.) oscillations.
- The shunt type ohmmeter is NOT suitable for high resistance measurements because:
-
View Hint View Answer Discuss in Forum
The shunt type ohm meter is not suitable for high resistance measurements because scale is highly cramped for high resistance values.
Correct Option: B
The shunt type ohm meter is not suitable for high resistance measurements because scale is highly cramped for high resistance values.