Electronic measurements and instrumentation miscellaneous


Electronic measurements and instrumentation miscellaneous

Electronic Measurements And Instrumentation

  1. An LVDT is used to measure displacement. The output of the LVDT is connected to a voltmeter of range 0 to 5V through an amplifier having a gain of 250. For a displacement of 0·5 mm, the output of the LVDT is 2 mV. The sensitivity of the instrument would be:









  1. View Hint View Answer Discuss in Forum

    Sensitivity of LVDT =
    output voltage
    displacement

    =
    2mV
    0·5mm

    = 1V/mm.

    Correct Option: C

    Sensitivity of LVDT =
    output voltage
    displacement

    =
    2mV
    0·5mm

    = 1V/mm.


  1. The deflection of hot wire instruments depends on:









  1. View Hint View Answer Discuss in Forum

    The deflection of not wire instruments depends on r.m.s. value of alternating current.

    Correct Option: C

    The deflection of not wire instruments depends on r.m.s. value of alternating current.



  1. Two voltmeters one with a full scale reading of 100 V and another with a full scale reading of 200 V, are connected in series across a 100 V supply. The internal resistance of both meters is the same. What are the readings?









  1. View Hint View Answer Discuss in Forum

    The given problem can be better understand by the figure given below:
    Since both the voltmeter have same internal resistance and the voltmeter are connected in series across a 100V supply. Hence the reading of both the voltmeters will be same i.e. 50V.


    Correct Option: D

    The given problem can be better understand by the figure given below:
    Since both the voltmeter have same internal resistance and the voltmeter are connected in series across a 100V supply. Hence the reading of both the voltmeters will be same i.e. 50V.



  1. Which bridge is used for measuring audio and H.F. oscillations?









  1. View Hint View Answer Discuss in Forum

    Wein bridge is used for measuring audio and High frequency (H.F.) oscillations.

    Correct Option: A

    Wein bridge is used for measuring audio and High frequency (H.F.) oscillations.



  1. The shunt type ohmmeter is NOT suitable for high resistance measurements because:









  1. View Hint View Answer Discuss in Forum

    The shunt type ohm meter is not suitable for high resistance measurements because scale is highly cramped for high resistance values.

    Correct Option: B